CONTROLLER M221-24IO TRANSISTOR PNP ETHERNET COMPACT

Kode Produk TM221CE24T
Nama Produk CONTROLLER M221-24IO TRANSISTOR PNP ETHERNET COMPACT
Keterangan MODICON M221 LOGIC KONTROLER SCHNEIDER ELECTRIC - TM221CE24T
Brand Schneider Electric
Tipe Logic Kontroler
Kode Produk : TM221CE24T Brand : Schneider Electric Nama Produk : CONTROLLER M221-24IO TRANSISTOR PNP ETHERNET COMPACT Keterangan : MODICON M221 LOGIC KONTROLER SCHNEIDER ELECTRIC - TM221CE24T

This TM221 controller is part of the Modicon M221 Logic controller range. It has 24 logic I/O and it is supplied with 24V DC. It is supplied with removable screw terminal blocks for connecting the I/O, a removable screw terminal block for connecting the power supply, a button cell backup battery BR2032 and a cable for connecting the analog inputs. M221 logic controllers have three types of integrated communication port, Ethernet, RS 232/RS 485 serial link and USB mini-B programming port. It enables the control of simple machines. The capacity of M221 logic controllers can be enhanced with the Modicon TM3 expansion module offer.

Specification
Supporting protocol for IEC 60870 FALSE
Supporting protocol for DNP3 FALSE
Supporting protocol for SERCOS FALSE
Number of HW-interfaces parallel 0
Number of interfaces PROFINET 0
Number of HW-interfaces other 0
Number of HW-interfaces USB 1
SIL according to IEC 61508 None
Number of relay outputs 0
With optical interface FALSE
Max. number of time switches 255
Additional program memory possible TRUE
Number of HW-interfaces wireless 0
System accessory FALSE
Performance level according to EN ISO 13849-1 None
Certified for UL hazardous location division 2 FALSE
Radio standard GPRS FALSE
Height 103.6 Millimetre
Supporting protocol for INTERBUS-Safety FALSE
Certified for UL hazardous location class I FALSE
Certified for UL hazardous location class III FALSE
Certified for UL hazardous location division 1 FALSE
Certified for UL hazardous location class II FALSE
Width 110 Millimetre
Supporting protocol for EtherCAT FALSE
Redundancy FALSE
Supporting protocol for AS-Interface Safety at Work FALSE
Radio standard GSM FALSE
Explosion safety category for dust None
Radio standard UMTS FALSE
Depth 75.9 Millimetre
Explosion safety category for gas None
Supporting protocol for DeviceNet Safety FALSE
Supporting protocol for EtherNet/IP FALSE
Supporting protocol for Foundation Fieldbus FALSE
Certified for UL hazardous location group C (ethylene) FALSE
Certified for UL hazardous location group A (acetylene) FALSE
Certified for UL hazardous location group B (hydrogen) FALSE
Certified for UL hazardous location group F (carbonaceous dusts) FALSE
Certified for UL hazardous location group G (non-conductive dusts) FALSE
Certified for UL hazardous location group D (propane) FALSE
Certified for UL hazardous location group E (metal dusts) FALSE
With display FALSE
Supporting protocol for SafetyBUS p FALSE
Processing time (1K, binary operation) 0.2 Millisecond
Model Compact
Voltage type (supply voltage) DC
Type of memory RAM
Long-Term Evolution (LTE) FALSE
Supporting protocol for PROFINET CBA FALSE
Supporting protocol for PROFINET IO FALSE
Memory size 512 kiloByte (1000 Byte)
Supporting protocol for PROFIsafe FALSE
Radio standard Bluetooth FALSE
Supporting protocol for ASI FALSE
Supporting protocol for PROFIBUS FALSE
Appendant operation agent (Ex ia) FALSE
Radio standard WLAN 802.11 FALSE
Front built-in possible FALSE
Supporting protocol for TCP/IP TRUE
Supporting protocol for KNX FALSE
Appendant operation agent (Ex ib) FALSE
Supporting protocol for CAN FALSE
IO link master FALSE
Supporting protocol for INTERBUS FALSE
Supporting protocol for IEC 61850 Ethernet FALSE
Rail mounting possible TRUE
Supporting protocol for DeviceNet FALSE
Number of digital outputs 10
Suitable for safety functions FALSE
Supporting protocol for Modbus TRUE
Supporting protocol for Data-Highway FALSE
Number of digital inputs 14
Number of analogue outputs 0
Supply voltage DC 19.2…28.8 Volt
Rack-assembly possible FALSE
Number of analogue inputs 2
Supporting protocol for LON FALSE
Supporting protocol for other bus systems FALSE
Supporting protocol for SUCONET FALSE
Number of HW-interfaces RS-422 0
Wall mounting/direct mounting TRUE
Number of HW-interfaces RS-485 1
Number of HW-interfaces industrial Ethernet 1
Number of HW-interfaces RS-232 1
Documents
Image of product
Image of product

Chat untuk Stock

Rp.5.797.514,-

33% Rp.8.653.005,-

Add to Cart

Free Ongkir Jabodetabek Menggunakan Kurir Toko Listrikkita

WhatsApp