This product is part of the Modicon M251 range, an offer of logic controllers for modular and distributed architectures. This logic controller provides 7 local, 14 remote I/O expansion modules. It is a Modicon logic controller with a rated supply voltage of 24V DC, an inrush current of 50A and a power consumption of 32.6W to 40.4W. Boost the performance of machine with powerful data transfer via SD Card, embedded web and FTP server and more. Integrated connections are USB port with mini B USB 2.0 connector, non isolated serial link serial with RJ45 connector and RS232/RS485 interface, dual-port Ethernet with RJ45 connector and CANopen J1939 with 9-way D-Sub (DE-09) connector. It is a Modicon M251 controller with 8MB for program, 64MB for system memory RAM, 128MB built-in flash memory for backup of user programs and a SD card memory capacity of 32GB. It is an IP20 rated product. Its dimensions are 54mm (Width) x 95mm (Depth) x 90mm (Height). It weighs 0.22kg. The Modicon M251 logic controllers are designed for high-performance compact machines incorporating speed and position control functions. This product is certified by CE, CSA and CULus. It meets ANSI/ISA 12-12-01, CSA C22.2 No 142, CSA C22.2 No 213, EN/IEC 61131-22007, marine specification (LR, ABS, DNV, GL), UL 1604 and UL 508 standards. It supports DIN rail mount. Achieve benchmark performance while increasing profitability with the Modicon M251 through intuitive machine programming with SoMachine, ready-to-use applications and function blocks. Increase flexibility, while saving space in your cabinet with the Modicon M251 logic controller for modular and distributed architectures.

Specification
Supporting protocol for IEC 60870 FALSE
Supporting protocol for DNP3 FALSE
Number of HW-interfaces parallel 0
Supporting protocol for SERCOS FALSE
Number of interfaces PROFINET 0
Number of HW-interfaces other 0
Number of HW-interfaces USB 1
SIL according to IEC 61508 None
Number of relay outputs 0
Max. number of time switches 0
With optical interface FALSE
Number of HW-interfaces wireless 0
System accessory FALSE
Additional program memory possible TRUE
Performance level according to EN ISO 13849-1 None
Certified for UL hazardous location division 2 FALSE
Radio standard GPRS FALSE
Height 90 Millimetre
Supporting protocol for INTERBUS-Safety FALSE
Certified for UL hazardous location class I FALSE
Certified for UL hazardous location class III FALSE
Certified for UL hazardous location division 1 FALSE
Certified for UL hazardous location class II FALSE
Width 54 Millimetre
Supporting protocol for EtherCAT FALSE
Redundancy FALSE
Supporting protocol for AS-Interface Safety at Work FALSE
Explosion safety category for dust None
Radio standard GSM FALSE
Radio standard UMTS FALSE
Depth 95 Millimetre
Explosion safety category for gas None
Supporting protocol for DeviceNet Safety FALSE
Supporting protocol for EtherNet/IP TRUE
Supporting protocol for Foundation Fieldbus FALSE
Certified for UL hazardous location group C (ethylene) FALSE
Certified for UL hazardous location group A (acetylene) FALSE
Certified for UL hazardous location group B (hydrogen) FALSE
Certified for UL hazardous location group F (carbonaceous dusts) FALSE
Certified for UL hazardous location group G (non-conductive dusts) FALSE
Certified for UL hazardous location group D (propane) FALSE
Certified for UL hazardous location group E (metal dusts) FALSE
With display FALSE
Processing time (1K, binary operation) 0.022 Millisecond
Model Modular
Supporting protocol for SafetyBUS p FALSE
Voltage type (supply voltage) DC
Type of memory NVRAM
Supporting protocol for PROFINET CBA FALSE
Long-Term Evolution (LTE) FALSE
Supporting protocol for PROFINET IO FALSE
Supporting protocol for PROFIsafe FALSE
Memory size 64000 kiloByte (1000 Byte)
Supporting protocol for ASI FALSE
Radio standard Bluetooth FALSE
Supporting protocol for PROFIBUS FALSE
Radio standard WLAN 802.11 FALSE
Appendant operation agent (Ex ia) FALSE
Supporting protocol for TCP/IP TRUE
Front built-in possible FALSE
Supporting protocol for KNX FALSE
Appendant operation agent (Ex ib) FALSE
Supporting protocol for CAN TRUE
IO link master FALSE
Supporting protocol for INTERBUS FALSE
Supporting protocol for IEC 61850 Ethernet FALSE
Rail mounting possible TRUE
Supporting protocol for DeviceNet FALSE
Number of digital outputs 0
Supporting protocol for Modbus TRUE
Suitable for safety functions FALSE
Number of digital inputs 0
Supporting protocol for Data-Highway FALSE
Number of analogue outputs 0
Supply voltage DC 19.2…28.8 Volt
Rack-assembly possible FALSE
Number of analogue inputs 0
Supporting protocol for LON FALSE
Supporting protocol for other bus systems FALSE
Supporting protocol for SUCONET FALSE
Wall mounting/direct mounting TRUE
Number of HW-interfaces RS-422 0
Number of HW-interfaces RS-485 1
Number of HW-interfaces industrial Ethernet 2
Number of HW-interfaces RS-232 1