Keterangan MCCB COMPACT NS1000N SCHNEIDER ELECTRIC - 33475
Brand Schneider Electric
Poles 4P
Rated Current 400-1000A
Breaking Capacity 50kA
Tipe Compact NS

Molded Chase Circuit Breaker (MCCB) is an electrical component that functions as a safety and circuit breaker when a short circuit or overload occurs, which can cause damage to the electric motor and fire due to sparks. MCCB is more popularly used as security for large-scale electrical installations, for example, in malls, factories, offices, and various other industries. MCCB usually uses 3 phases because it is only used as a safety measure for electric motors in the industrial world. MCCB also has several pole options, namely, 1 pole, 2 poles, 3 poles, and 4 poles.

Characteristics of Moulded Chase Circuit Breaker (MCCB) : 

  • Uses three phases.
  • Ampere Rating: 100A–1000A
  • Network frequency: 50/60 Hz
  • Using thermal magnetic
  • Can be set to Fixed or Adjustment

The main function of an MCCB (Molded Case Circuit Breaker) is as a protection device for electrical equipment against short circuits or excess electric current (overload) so as to avoid damage and fire. The MCCB device is equipped with a temperature sensor and current sensor feature so that this device is able to work automatically based on current and temperature conditions. In general, MCCB has a greater function than MCB because its specifications are greater and it uses 3 phases. Therefore, this device is only used as protection for electric motors in the industrial world.

Schneider MCCB ComPact NS800/1600 N/H Manually Operated

Provides instructions regarding the cause of the circuit breaker tripping.

  • Nominal Current (In):
    NS800: 800A      NS1250: 1250A
    NS1000: 1000A; NS1600: 1600A
  • Termination Capacity: 50 to 150 kA at 380/415 VAC.
  • Trip unit (1):
    • Micrologic 2.0: Standard electronic trip unit for distribution load protection.
    • Micrologic 5.0: Electronic trip unit for distribution load protection with discrimination amplifier.
  • Fixed type, front connection.
  • Equipped with a 220V AC
  • Motor mechanism module that meets IEC 60947-2 standards.

ListrikKita.com sells several brands, namely Schneider Electric, ABB, Siemens, Fuji Electric, LS Electric, Nidec, Socomec, L&T, Ducati Energia, Chint, Hager, Nader, Axle, Lifasa, Himel, APC, Hensel, Philips, GE Current, Simon, Hannochs, Nusa, Gesits, U-Winfly, Hioki, TAC, Imou, Airquality, Legrand, Mennekes, Epcos, Safe-D-Lock, Leroy Somer, Allen-Bradley, Sunfree, Secure, Telergon, Circutor, OPT, CIC, PM, Supreme, Kabelindo, Kabelmetal Indonesia, Alpha, Selis, Telemecanique, Trafindo, Esitas, BOSS, B&D Transformer, Asco, Secure, Howig, Onesto, Veloce, and many more.

You can shop safely at ListrikKita.com because all the goods we sell are guaranteed to be 100% genuine, have an official guarantee, and can be accompanied by a letter of authenticity. To get the best prices and further information, please contact our sales or marketing team by clicking here. Happy shopping.

This Compact NS1000N is a complete 4 poles fixed circuit breaker designed to optimize space and breaking capacity. It is an optimal choice for all standard and specific applications. The breaking capacity (Icu) is 50kA rms at 415VAC 50/60Hz. The operational voltage is 690VAC 50/60Hz. The circuit breaker can be manually operated with ON, OFF or "push to trip" buttons. This product embeds an electronic Micrologic 2.0 trip unit, with 1000A rating. Micrologic 2.0 trip unit provides adjustable long time and instantaneous protections. This 4 poles version (327mm x 280mm x 147mm) comes with a variety of optional functions and accessories. It is compliant with IEC 69947-1 and IEC60947-2 international standards and marine specifications. Compact NS1000N is part of Schneider Electric EcoStruxure Power architecture.

Specification
Type of electrical connection of main circuit Screw connection
Complete device with protection unit TRUE
Type of control element Toggle
Number of auxiliary contacts as normally closed contact 0
DIN rail (top hat rail) mounting optional FALSE
Number of auxiliary contacts as change-over contact 0
Number of auxiliary contacts as normally open contact 0
With switched-off indicator TRUE
Overload release current setting 400…1000 Ampere
Rated permanent current Iu 1000 Ampere
Rated voltage 690 Volt
Position of connection for main current circuit Front side
Number of poles 4
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz 50 kiloampere
With integrated under voltage release FALSE
Motor drive integrated FALSE
Integrated earth fault protection FALSE
Adjustment range undelayed short-circuit release 1500…10000 Ampere
Power loss 88 Watt
Degree of protection (IP) IP40
Motor drive optional TRUE
Suitable for DIN rail (top hat rail) mounting FALSE
Device construction Built-in device fixed built-in technique